Now Serving All of Indiana - Licensed electricians dispatched from Indianapolis.

Emergency calls welcome: (317) 680-7907

Emergency Exit Lighting Installation

Kochs Electric installs compliant, fully tested emergency exit lighting systems and equipment for commercial and residential properties across the region. Our reliable exit lighting services cover installation, maintenance, and inspections – ensuring every light is safe, properly installed, and built to last.

State Licensed
Master Electricians
Permit & Inspection Handled
24-Hour Emergency Line
Workmanship Guaranteed

Licensed, Bonded & Insured

NEC Code Compliant

Same-Day Emergency Response

Permits Pulled & Inspections Managed

Workmanship Guarantee

Serving All of Indiana

5 Highlights on Emergency Exit Lighting Installation

Full NFPA 101 and NEC Article 700 compliance

Every emergency exit lighting installation Kochs Electric completes is designed to meet current NFPA 101 Life Safety Code, NEC Article 700 emergency system requirements, and local fire safety standards, ensuring signed certification and a completed logbook handed to the client on the day.

Self-contained and central-battery systems 

We install both self-contained maintained luminaires and central-battery hardwired systems with reliable battery backup, selecting the right configuration based on your escape route layout, occupancy load, and building compartment design.

Lux level and duration testing

Every fitting is discharge-tested to confirm the rated illumination level at floor level across corridors, stairwells, and assembly points, ensuring proper functioning with full lumen and candela output verified against the installation schedule.

Surface-mounted and recessed options

We mount quality LED and fluorescent emergency lights flush or surface-mounted, weatherproof or flameproof rated, depending on the enclosure type and the environment.

Pictographic exit signs and directional arrows

We supply and install photoluminescent and illuminated exit signs, directional pictograms, and legend plates positioned for maximum visual clarity and visibility along every designated emergency route.

460+
Homes Serviced
92%
Same-Day Response
4+
Years of Experience
100%
Code-Compliant Work

Why Choose Our Emergency Exit Lighting Installation

Kochs Electric – founded by Master Electrician David Koch (Indiana License #EC21400047) and serving Indiana businesses since 2008 – has built a trusted reputation for professional exit lighting services across commercial premises, fire-rated buildings, and multi-occupancy sites. Our skilled technicians handle every project from initial assessment to final handover.

Our qualified electricians and certified inspectors carry out every installation from first fix through to final commissioning. We don’t subcontract – our own employees handle every stage. The same team that wires your distribution board and routes your conduit also terminates your luminaire connections, tests your circuits, and signs your certificate.

We work with non-maintained, maintained, and sustained emergency lighting configurations. We know when a self-contained rechargeable battery fitting suits a small corridor and when a central-battery inverter system is the right call for a large multi-floor building. That knowledge ensures every system operates properly and remains reliable in operation – ready when it matters most.

Every job includes detailed inspections, a full inspection report, a completed test sheet, and a risk assessment. We label every circuit, log every fitting, and hand you documentation that satisfies your fire safety assessor, your insurance provider, and your local authority.

Our electricians hold current qualifications and carry out work to NFPA 101 Life Safety Code and NEC Article 700. We offer routine maintenance plans with regular testing and annual testing schedules – including return visits for annual discharge testing so your system stays compliant year after year.

Kochs Electric is the top-rated choice for expert emergency exit lighting installation – reliable, thorough, and fully accountable on every job, ensuring your system is always ready when it counts.

Recent projects include a full emergency lighting upgrade across a 4-story Indianapolis office building – 52 LED emergency luminaires on dedicated circuits across all four floors, NFPA 101-compliant test documentation completed and handed to the facility manager at final inspection; and a warehouse distribution center in Carmel where we installed exit signs and emergency lighting across 80,000 sq ft, completing all work during off-hours to avoid production downtime. Call (317) 680-7907 to discuss your compliance requirements.

 

emergency exit lighting installation square
residential electrical services wide

Ready to Get Started?

Contact our licensed team today for a clear, written quote with no surprises. We serve all of Indiana.

Call (317) 680-7907

Signs You Need Emergency Exit Lighting Installation

1

Your exit signs are missing or obstructed:

If your escape route has no illuminated or photoluminescent exit sign at each decision point, you’re non-compliant. Carry out a visual walk-through and check for visible damage, obstructions, or missing signs. Signs must be legible, visible, and unobstructed at all times. A missing pictogram above a fire door or a blocked directional arrow in a corridor puts occupants at risk and exposes you to enforcement action.

2

Your luminaires fail the duration test:

Emergency luminaires must sustain rated lux output for a minimum of one hour – three hours in some occupancy categories. If your fittings cut out early during a discharge test, the batteries are degraded and the units need replacement. Kochs Electric carries out full duration testing and provides repair services, including swapping out faulty self-contained or central-battery fittings on the same visit.

3

Your building has been refurbished or reconfigured:

Any change to internal walls, ceilings, or escape routes can create issues with your existing emergency lighting layout. New corridors, relocated stairwells, or added fire doors all require a fresh zone and coverage assessment. We review your floor plan, update the schematic, and install additional luminaires to ensure full coverage along every escape route.

4

Your system has no test record or logbook:

A compliant emergency exit lighting installation requires regular maintenance and a maintained logbook with dated entries for every function test, discharge test, and inspection – including monthly checks and a full annual test. No logbook means no audit trail. Kochs Electric sets up your log, completes the first entries, and schedules your ongoing testing program.

5

Your fittings are fluorescent, aged, or defective:

Older fluorescent emergency luminaires draw more wattage, carry degraded ballast gear, and deliver lower lumen output than current LED equivalents. Defective or faulty fittings that fail to illuminate on activation are a direct compliance failure. We handle all repair and replacement work – fitting rated LED luminaires, re-terminating the wiring, and re-testing the circuit to confirm proper functioning.

Fully Licensed & Insured

State of Indiana

We Pull All Permits

You don’t lift a finger

NEC Code Compliant
Every project, every time
Workmanship Guarantee
We come back if anything fails

Our Emergency Exit Lighting Installation Process

1

Site Survey and Risk Assessment

We visit your premises, walk every escape route, and carry out a detailed assessment of your corridors, stairwells, fire doors, and assembly points. We measure lux levels, check existing coverage, and identify gaps in your current layout.

2

System Design and Schedule

We produce a floor plan schematic showing luminaire positions, circuit zones, and fitting types. We specify whether a self-contained or central-battery system suits your building and confirm that each fitting meets the wattage, lumen output, and duration requirements.

3

First Fix Wiring

Our electricians route conduit or trunking, pull cable, and chase containment where required. We wire back to the panel board, install the correct circuit breaker protection, and earth and bond all metalwork.

4

Luminaire Installation and Termination

We mount each luminaire – surface-mounted, recessed, or flush – secure the backplate and housing, terminate the conductors at the terminal block, and connect the CPC. We fit exit signs, directional arrows, and legend plates at the correct height and angle.

5

Testing and Commissioning

We carry out continuity, insulation resistance, polarity, and earth fault loop impedance tests on every circuit. We run a full discharge test on each fitting, verify lux levels at floor level, and confirm duration performance – ensuring every light is safe, reliable, and meets quality requirements.

6

Certification and Handover

We complete the NFPA 101 Life Safety Certificate, sign the inspection report, fill in the logbook, and hand you the full documentation pack.

Brands We Use

Kochs Electric installs emergency exit lighting products from the most trusted manufacturers in the industry. Every brand we specify meets NFPA 101 and NEC Article 700 requirements and carries the relevant UL safety certifications.

Zumtobel
Zumtobel
Legrand
Legrand
Eaton
Eaton
Hochiki 
Hochiki
Lithonia Lighting 
Lithonia Lighting 
Thorn Lighting
Thorn Lighting
Zumtobel
Zumtobel
Legrand
Legrand
Eaton
Eaton
Hochiki 
Hochiki
Lithonia Lighting 
Lithonia Lighting 
Thorn Lighting
Thorn Lighting

Every product we install is sourced from verified suppliers, correctly rated for the installation environment, and tested on-site before we sign the certificate.

Other Services

Emergency exit lighting installation

Emergency lighting installation service

BS5266 emergency lighting compliance

Emergency exit light fitting

Exit sign installation electrician

Self-contained emergency luminaire wiring

Commercial emergency lighting installation

Emergency lighting system installation

Central-battery emergency lighting setup

Emergency lighting testing and certification

Emergency light inspection and testing

Duration test discharge test emergency lighting

Emergency exit sign installation

Illuminated exit sign fitting service

Photoluminescent exit sign installation electrician

Exit lighting services

Repair services emergency lighting

Routine maintenance emergency lighting

Regular testing emergency exit lights

Annual testing emergency lighting

Life safety code compliance lighting

FAQs About Emergency Exit Lighting Installation

Emergency exit lighting installation is the process of wiring, mounting, testing, and certifying equipment including luminaires and exit signs that activate automatically when the mains supply fails. The system provides illumination along escape routes, corridors, stairwells, and exit doors so occupants can evacuate safely. Properly installed and maintained life safety lighting ensures your building is always ready and compliant.

Any building with an occupancy load above a single dwelling requires compliant emergency lighting to meet life safety code requirements. This includes offices, retail premises, warehouses, schools, care homes, and multi-unit residential blocks. If your building has a designated escape route, it needs emergency lighting installed and maintained to NFPA 70 and any applicable safety code.

Batteries degrade over time. A fitting that looks operational may fail to sustain rated lux output during an actual power failure. Regular testing – including monthly function checks and annual testing discharge cycles – confirms that every luminaire activates, illuminates, and holds output properly for the required duration, typically one to three hours depending on occupancy category.

A self-contained fitting contains its own rechargeable battery, charging circuit, and lamp driver. It stays connected to the mains supply to keep the battery charged. When the supply is interrupted, the fitting detects the loss of power and switches to battery automatically, activating the lamp within five seconds.

Yes. We carry out full replacement of existing fluorescent emergency luminaires with quality LED equivalents, re-terminate the wiring, update the installation schedule, and re-test the full circuit. If only some fittings have issues, we also offer targeted repair services. LED fittings draw less wattage, deliver higher lumen output, and carry longer battery backup life than fluorescent units.

Yes. Every emergency exit lighting installation we complete includes a signed NFPA 101 installation certificate, a detailed inspection report, a test sheet, and a logbook covering all inspections carried out. This documentation helps satisfy your fire safety assessor, insurer, and local authority. You receive the full documentation pack at handover.

Contact Kochs Electric to get a quote for new installation, routine maintenance, or emergency repairs. Our technicians are ready to assess your building, identify any issues, and recommend the right solution – whether that’s a full system install, a replacement fitting, or targeted repairs to get your existing system functioning properly. Call us at (317) 680-7907 or email [email protected].

Same-Day Emergency Dispatch Available

Indiana's Trusted Residential Electricians

Licensed. Insured. NEC compliant. We pull permits and schedule inspections so you don’t have to. Call us today to get started.